FLEXCAB LINE Alarm cables
Print product sheetBenefits:
- Pre-wired pliable corrugated conduit with alarm cables
- Save time: installation times are halved
- Save money and workforce: one person can easily do the job alone
- Maximize safety: no risks of damaging the cables during puling operations
- Within the conduit, there is enough space left to add other cables after the installation. Thanks to the internal lubrication, in-pulling and out-pulling operations are very easy
- Metrically marked
- Ecological conduit: LSF0H (Low Smoke Fire Resistant Zero Halogen), ideal for installations in buildings aimed at hosting high numbers of people, such as schools, hospitals, stations, museums, shopping malls, etc.
Usage Areas:
Outdoor | |
Indoor | |
Exposed Installation | |
Liquid screed and concrete | |
Chased wall - Plasterboard | |
Chased floor | |
False ceiling - Movable wall | |
Prefab - Wood panels |
Conduit Technical Specification
Material | Polypropylene |
Compression resistance | 750N (23°C, +/-2°C) |
Resistance to impact | 6J (IK08) |
Minimum operating temperature | -5°C |
Maximum operating temperature | +90°C |
Bending resistance | Pliable - Self-recovering |
Insulation resistance | >100MΩ |
Glow Wire Test (IEC EN 60695-2) | 960°C |
Cable Technical Specification
Type | Alarm | Alarm |
Code | ALL | ALLHF |
Function | Alarm | Alarm |
Outer Sheath | PVC | LSZH compound |
Rated Voltage | 400 V | 400 V |
Bending Radius | 15XØ | 15XØ |
Operating Temperature | -10°C/+70°C | -10°C/+70°C |
C.P.R. Euroclass | Eca | Cca, s1d1a1 |
Material Properties
FEATURES | STANDARD | YES/NO |
---|---|---|
LS - Low Smoke | IEC 61034-2 | |
0H - Zero Halogen | IEC 60754-1; IEC 60754-2 | |
Fire resistant | EN 61386.1, EN 61386.22 | |
Self-recovering (of at least 90% of original diameter) | EN 61386.1, EN 61386.22 | |
Packed with 100% recyclable PE film |